(*) - local vPC is down, forwarding via vPC peer-linkĬonfiguration consistency status : successĭelay-restore status : Timer is off.(timeout = 30s)ĭelay-restore SVI status : Timer is off.(timeout = 10s) To verify, use need to use, “show vpc brief” command. Nexus-2(config-if)# switchport mode trunk Nexus-2(config)# interface port-channel 20 Nexus-2(config-if-range)# channel-group 20 mode active Nexus-2(config)# interface ethernet 1/1-2 Nexus-1(config-if)# switchport mode trunk Nexus-1(config)# interface port-channel 20 Nexus-1(config-if-range)# channel-group 20 mode active Nexus-1(config)# interface ethernet 1/1-2 The peer link exchanges state information and carries control traffic between peer nexus switches. Nexus-2(config-vpc-domain)# peer-keepalive destination 10.1.1.1 source 10.1.1.2 vrf management Nexus-1(config-vpc-domain)# role priority 30 Nexus-1(config-vpc-domain)# peer-keepalive destination 10.1.1.2 source 10.1.1.1 vrf management Nexus-1(config-vpc-domain)# role priority 20 And, also we will set priorities for both switches. In this example, we will be using vPC domain 1. Round-trip min/avg/max = 0.503/0.683/1.098 msĪ vPC domain is a collection of vPC component. To verify the connectivity, we can ping from Nexus-1 to Nexus-2 management IP.